{"id":2025,"date":"2026-11-11T06:47:34","date_gmt":"2026-11-11T06:47:34","guid":{"rendered":"https:\/\/service.soletksolar.com\/solar-space-heating-combisystem-design\/"},"modified":"2026-11-11T06:54:50","modified_gmt":"2026-11-11T06:54:50","slug":"solar-space-heating-combisystem-design","status":"publish","type":"post","link":"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/","title":{"rendered":"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide"},"content":{"rendered":"<div class=\"stk-g\">\n<style>.stk-g{color:#20324b;font:16px\/1.75 Inter,'Segoe UI',Arial,sans-serif;max-width:920px;margin:0 auto;padding:0 16px 48px;overflow-wrap:break-word}.stk-g *{box-sizing:border-box}.stk-g a{color:#175bb8}.stk-g h1{font-size:clamp(30px,4vw,44px);line-height:1.18;color:#fff;margin:0 0 16px}.stk-g h2{font-size:clamp(23px,2.6vw,30px);line-height:1.28;color:#122b46;margin:40px 0 14px}.stk-g h3{font-size:19px;color:#173c5d;margin:24px 0 8px}.stk-g p{margin:0 0 14px}.stk-g ul,.stk-g ol{margin:0 0 16px;padding-left:22px}.stk-g li{margin:0 0 6px}.stk-g .hero{background:linear-gradient(118deg,#0c1b2f,#183758);color:#e2ebf5;border-radius:16px;padding:clamp(24px,5vw,48px);margin:16px 0 26px}.stk-g .hero p{margin:0}.stk-g .ans{background:#f5f8fc;border:1px solid #dce5ee;border-left:4px solid #e66a26;border-radius:10px;padding:18px 20px;margin:0 0 24px}.stk-g .ans p:last-child{margin-bottom:0}.stk-g figure{margin:22px 0}.stk-g figure.p{max-width:340px;margin:22px auto}.stk-g img{display:block;max-width:100%;height:auto;border-radius:10px}.stk-g figcaption{font-size:13px;color:#5a6c82;margin-top:6px}.stk-g .t{overflow-x:auto;border:1px solid #dce5ee;border-radius:10px;margin:14px 0 20px}.stk-g table{border-collapse:collapse;width:100%;min-width:560px;font-size:14.5px}.stk-g th{background:#173451;color:#fff;text-align:left;padding:10px 12px}.stk-g td{padding:10px 12px;border-top:1px solid #e8eef3;vertical-align:top}.stk-g .cta{background:#fff7f0;border:1px solid #f4d2b8;border-radius:12px;padding:20px 22px;margin:30px 0}.stk-g .cta p:last-child{margin-bottom:0}.stk-g .note{font-size:13.5px;color:#5a6c82}<\/style>\n<article>\n<header class=\"hero\">\n<h1>Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide<\/h1>\n<p>Match the collectors, buffer tank, heat emitters and backup heat so solar actually reaches your radiators and floors.<\/p>\n<p style=\"margin-top:12px;font-size:13px;color:#b8c7d9\">Last updated: November 11, 2026<\/p>\n<\/header>\n<div class=\"ans\">\n<p><strong>Quick answer:<\/strong> pair solar with low-temperature heat emitters, ideally underfloor or wall heating at about 30\u201340 \u00b0C. Size the buffer tank at roughly 50\u2013100 litres per m\u00b2 of collector, and always size the backup heater for 100% of the design heat load. In a well-insulated house, expect solar to cover about 20\u201340% of heating demand, and less in older buildings.<\/p>\n<p>Plan the summer surplus at the same time, or the collector field will overheat.<\/p>\n<\/div>\n<p>Most solar thermal systems are built for one job: domestic hot water. But in cold and sunny regions, <strong>space heating<\/strong> is often the largest energy demand in a building. A solar space heating system that supports both hot water and heating is called a <strong>solar combisystem<\/strong>.<\/p>\n<p>Combisystems are more complex than hot-water-only systems. The heating demand is highest in winter, when solar gain is lowest. Good design is about matching the collector field, the buffer tank, the heat distribution system and the backup heat source so they work together.<\/p>\n<p>This guide explains how to plan a solar space heating system for villas, apartment buildings, schools and public buildings.<\/p>\n<h2>How a Solar Combisystem Works<\/h2>\n<p>A typical combisystem has five main parts:<\/p>\n<ol type=\"1\">\n<li><strong>Campo collettore<\/strong> \u2013 flat plate, evacuated tube or PVT collectors on the roof or ground<\/li>\n<li><strong>Buffer (combi) tank<\/strong> \u2013 stores solar heat for both heating and hot water, often stratified<\/li>\n<li><strong>Domestic hot water preparation<\/strong> \u2013 an internal coil, a tank-in-tank design, or an external fresh water station<\/li>\n<li><strong>Heat distribution<\/strong> \u2013 underfloor heating, wall heating, low-temperature radiators or fan coils<\/li>\n<li><strong>Backup heat source<\/strong> \u2013 heat pump, gas or biomass boiler, or electric heater<\/li>\n<\/ol>\n<p>The solar loop charges the buffer tank. The heating circuit and hot water system take heat from the tank. When solar heat is not enough, the backup heater keeps the top of the tank at the required temperature.<\/p>\n<h2>Step 1: Understand the Heating Load<\/h2>\n<p>Before sizing any collectors, you need to know the building&#8217;s heat demand:<\/p>\n<ul>\n<li><strong>Design heat load (kW)<\/strong> \u2013 the peak heating power needed on the coldest day<\/li>\n<li><strong>Annual heating demand (kWh\/year)<\/strong> \u2013 the total energy for the whole heating season<\/li>\n<li><strong>Hot water demand (kWh\/year)<\/strong> \u2013 often 10\u201330% of total demand in a heated residential building, and a higher share in well-insulated new buildings<\/li>\n<\/ul>\n<p>Building insulation makes a big difference. A well-insulated new building may need a fraction of the heat of an old building with the same floor area. For an existing building, real fuel bills from the last two or three winters are the best starting point.<\/p>\n<h2>Step 2: Choose the Right Heat Distribution System<\/h2>\n<p>Il <strong>supply temperature<\/strong> of the heating system decides how much solar heat can be used. Lower temperature means higher collector efficiency and more useful solar hours.<\/p>\n<div class=\"t\">\n<table>\n<thead>\n<tr>\n<th>Heat distribution<\/th>\n<th>Typical supply temperature<\/th>\n<th>Solar suitability<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Underfloor \/ wall heating<\/td>\n<td>approx. 30\u201340 \u00b0C<\/td>\n<td>Eccellente<\/td>\n<\/tr>\n<tr>\n<td>Low-temperature radiators \/ fan coils<\/td>\n<td>approx. 40\u201355 \u00b0C<\/td>\n<td>Buono<\/td>\n<\/tr>\n<tr>\n<td>Standard radiators (old buildings)<\/td>\n<td>approx. 60\u201375 \u00b0C<\/td>\n<td>Limitata<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Underfloor heating is the best partner for solar.<\/strong> The concrete floor also works as extra thermal storage, so heat collected at midday is released slowly in the evening.<\/p>\n<p>For buildings with old high-temperature radiators, consider replacing some radiators or adding fan coils before investing in a large collector field.<\/p>\n<h2>Step 3: Size the Collector Area<\/h2>\n<p>There is no single rule, because climate, building and target solar fraction all differ. As a first estimate for planning:<\/p>\n<ul>\n<li><strong>Hot water only (residential):<\/strong> roughly 1\u20131.5 m\u00b2 collector per person<\/li>\n<li><strong>Combisystem (residential, well-insulated):<\/strong> a common starting point is about 1 m\u00b2 collector per 10 m\u00b2 of heated floor area. Use less in mild climates or for a low solar fraction, and more only if you also plan large storage and a summer heat use.<\/li>\n<\/ul>\n<p>Then check the design with a simulation tool or monthly energy balance:<\/p>\n<ul>\n<li>Calculate monthly solar yield of the collector field<\/li>\n<li>Compare it with the monthly heating + hot water demand<\/li>\n<li>Make sure the <strong>summer surplus<\/strong> is acceptable (see overheating section below)<\/li>\n<\/ul>\n<p><strong>Typical energy savings<\/strong> from combisystems in Central Europe or similar climates are roughly 20\u201340% of total heat demand in well-insulated houses, and lower in older buildings with high heat loss. For example, IEA SHC Task 26 simulations of a single-family house in Zurich found savings of about 23\u201339% when the collector area was varied from 4 to 20 m\u00b2, with a base case of 12 m\u00b2 of flat plate collectors and an 830-litre store. Higher values are possible with large storage or sunny winter climates (for example, high-altitude regions).<\/p>\n<h2>Step 4: Choose the Collector Type and Tilt<\/h2>\n<div class=\"t\">\n<table>\n<thead>\n<tr>\n<th>Collettore<\/th>\n<th>Strengths for space heating<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Flat plate collector<\/strong><\/td>\n<td>Cost-effective, robust, good for large fields and underfloor heating<\/td>\n<\/tr>\n<tr>\n<td><strong>Large size flat plate collector<\/strong><\/td>\n<td>Fewer connections and faster installation on big projects<\/td>\n<\/tr>\n<tr>\n<td><strong>Evacuated tube (CTC \/ HPC heat pipe)<\/strong><\/td>\n<td>Higher efficiency in cold weather and at higher temperatures; good for radiators and cold climates<\/td>\n<\/tr>\n<tr>\n<td><strong>PVT panel + heat pump<\/strong><\/td>\n<td>Produces electricity and low-temperature heat; the heat pump lifts the temperature for heating<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Tilt angle matters more for heating than for hot water.<\/strong> A steep tilt (often around 50\u201370\u00b0, or close to vertical on facades) increases winter yield, reduces summer overheating and helps snow slide off.<\/p>\n<figure class=\"p\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2025\/11\/flat-plate-solar-collector.jpg\" alt=\"SOLETKS flat plate solar thermal collector\" width=\"1653\" height=\"2336\"><figcaption>SOLETKS flat plate collector, a cost-effective choice for underfloor heating and large fields. Product image.<\/figcaption><\/figure>\n<h2>Step 5: Size the Buffer Tank<\/h2>\n<p>The buffer tank stores solar heat from sunny hours for use in the evening and on cloudy days.<\/p>\n<ul>\n<li>A common planning range is <strong>about 50\u2013100 litres of storage per m\u00b2 of collector<\/strong> for combisystems<\/li>\n<li>Larger storage increases solar fraction but also costs more, needs more space and has higher heat losses<\/li>\n<li><strong>Stratification<\/strong> is important: keep hot water at the top for domestic hot water and cooler water at the bottom so the collectors work at low temperature<\/li>\n<li>Use stratifying inlets, correct connection heights and low flow rates in the heating return<\/li>\n<\/ul>\n<p>For apartment buildings, schools and district systems, several tanks in series, or a large central tank, are common.<\/p>\n<h2>Step 6: Plan the Backup Heat Source<\/h2>\n<p>The backup heater must be able to cover <strong>100% of the design heat load<\/strong>, because there will be cloudy cold weeks with little solar heat.<\/p>\n<ul>\n<li><strong>Heat pump:<\/strong> the best partner for low-temperature underfloor heating. Solar raises the source or tank temperature, which improves heat pump efficiency.<\/li>\n<li><strong>Gas or biomass boiler:<\/strong> common in retrofits. Make sure the boiler only heats the top part of the tank, so solar can use the lower part.<\/li>\n<li><strong>Electric heater:<\/strong> simple, but expensive to run; better for small systems or as an emergency backup.<\/li>\n<\/ul>\n<p>The controller should give solar priority: the backup heater starts only when solar cannot reach the required temperature.<\/p>\n<h2>Step 7: Control Summer Overheating<\/h2>\n<p>A combisystem has a large collector field for winter heating, but in summer only hot water is needed. This creates large surplus heat.<\/p>\n<p>Solutions include:<\/p>\n<ul>\n<li>Steeper tilt angles to reduce summer yield<\/li>\n<li>Heat dump to a pool, ground loop or other summer load<\/li>\n<li>Drainback design for buildings with long idle periods<\/li>\n<li>Correct expansion vessel sizing and controller protection functions<\/li>\n<\/ul>\n<p>See our guide to <a href=\"https:\/\/service.soletksolar.com\/it\/solar-collector-stagnation-overheating-protection\/\">solar collector stagnation and overheating protection<\/a> for details.<\/p>\n<h2>Project Example: Centralized Solar Heating in Saga County, Shigatse<\/h2>\n<p>One of SOLETKS&#8217; featured projects is the <strong>Centralized Solar Heating project for Saga County Town in Shigatse City, Tibet (2019)<\/strong>. High-altitude regions like this have very strong solar radiation and long, cold heating seasons, which makes them one of the best climates for solar space heating.<\/p>\n<p>See the full project on our <a href=\"https:\/\/service.soletksolar.com\/it\/featured-projects\/\">Featured Projects page<\/a>.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2026\/06\/Centralized-solar-heating-for-Saga-County-town-in-Shigatse-City-1.png\" alt=\"Centralized solar heating project for Saga County town in Shigatse City, Tibet\" width=\"1254\" height=\"728\"><figcaption>Centralized solar heating for Saga County Town, Shigatse City (SOLETKS featured project, 2019).<\/figcaption><\/figure>\n<h2>Common Mistakes in Solar Space Heating Projects<\/h2>\n<ol type=\"1\">\n<li><strong>Using high-temperature radiators<\/strong> without adapting the heating system<\/li>\n<li><strong>Oversizing the collector field<\/strong> for winter, with no plan for summer surplus<\/li>\n<li><strong>Undersized or poorly stratified buffer tanks<\/strong><\/li>\n<li><strong>Backup heater heating the whole tank<\/strong>, which leaves no room for solar<\/li>\n<li><strong>No monitoring<\/strong>, so poor performance is never noticed<\/li>\n<\/ol>\n<h2>How SOLETKS Can Help<\/h2>\n<p>SOLETKS manufactures flat plate collectors, large size flat plate collectors, CTC and HPC evacuated tube collectors and PVT panels, with 7.0 GWth annual production capacity. For space heating projects, we can help with:<\/p>\n<ul>\n<li>Collector selection for your climate and heating system<\/li>\n<li>Collector field layout and hydraulic design<\/li>\n<li>Buffer tank, pump station and controller packages<\/li>\n<li>Technical documents for EPC contractors and distributors<\/li>\n<\/ul>\n<p>Related reading:<\/p>\n<ul>\n<li><a href=\"https:\/\/service.soletksolar.com\/it\/large-size-flat-plate-solar-collector-dimensions\/\">Large Size Flat Plate Solar Collector Dimensions and Performance Guide<\/a><\/li>\n<li><a href=\"https:\/\/service.soletksolar.com\/it\/pvt-solar-panels-with-heat-pump\/\">PVT Solar Panels with Heat Pump: Hybrid System Design and Applications<\/a><\/li>\n<li><a href=\"https:\/\/service.soletksolar.com\/it\/commercial-heat-pipe-solar-collector-cold-europe-design\/\">Progettazione di un collettore solare commerciale a tubi di calore per l\u2019Europa fredda<\/a><\/li>\n<li><a href=\"https:\/\/service.soletksolar.com\/it\/centralized-solar-water-heating-system\/\">Centralized Solar Water Heating System for Apartments, Schools and Campuses<\/a><\/li>\n<\/ul>\n<div class=\"cta\">\n<p><strong>Planning a solar heating project?<\/strong> <a href=\"https:\/\/service.soletksolar.com\/it\/contact\/\">Contact us<\/a> or send your building data via <a href=\"https:\/\/wa.me\/8619906378193\">WhatsApp<\/a>.<\/p>\n<\/div>\n<h2>Domande frequenti<\/h2>\n<h3>Can solar thermal heat a whole house?<\/h3>\n<p>In most climates, solar covers part of the heating demand, often about 20\u201340% in a combisystem for a well-insulated house, and less in older buildings. Full coverage needs very large seasonal storage. A backup heater is always required.<\/p>\n<h3>Is underfloor heating better than radiators for solar?<\/h3>\n<p>Yes. Underfloor heating works at about 30\u201340 \u00b0C, so collectors run more efficiently and deliver useful heat for more hours each day.<\/p>\n<h3>Flat plate or evacuated tube for solar space heating?<\/h3>\n<p>Flat plate collectors are cost-effective for underfloor heating and large fields. Evacuated tube collectors perform better in very cold weather and at higher supply temperatures.<\/p>\n<h3>How big should the buffer tank be?<\/h3>\n<p>A common planning range is about 50\u2013100 litres per m\u00b2 of collector area. The final size depends on the load profile, space and target solar fraction.<\/p>\n<h3>Can I combine solar heating with a heat pump?<\/h3>\n<p>Yes. This is one of the most efficient combinations. Solar or PVT collectors raise the tank or source temperature, and the heat pump covers the rest with a better efficiency.<\/p>\n<h2>Bibliografia<\/h2>\n<div class=\"note\">\n<ul>\n<li>IEA SHC Task 26 \u2013 Solar Combisystems: system descriptions and simulation results (iea-shc.org).<\/li>\n<\/ul>\n<\/div>\n<\/article>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Plan a solar space heating system for heating and hot water: load, collector area, buffer tank, underfloor vs radiators, backup and solar fraction.<\/p>","protected":false},"author":1,"featured_media":1706,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[],"class_list":["post-2025","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"lemonx_aeo_head":{"title":"Solar Space Heating Combisystem Design & Sizing | SOLETKS","description":"Plan a solar space heating system for heating and hot water: load, collector area, buffer tank, underfloor vs radiators, backup and solar fraction.","canonical":"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/","robots":"max-image-preview:large","og":{"type":"article","title":"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide","description":"Plan a solar space heating system for heating and hot water: load, collector area, buffer tank, underfloor vs radiators, backup and solar fraction.","image":"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2026\/06\/Centralized-solar-heating-for-Saga-County-town-in-Shigatse-City-1-1024x594.png","image_alt":"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide","url":"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/","site_name":"Solar Water Heater\uff5cSolar Collector\uff5cSolar Hot Water System\uff5cHybrid Solar Power System","locale":"it_IT"},"twitter":{"card":"summary_large_image"},"schema":[{"@type":"Organization","@id":"https:\/\/service.soletksolar.com\/it\/#organization","name":"Scaldacqua solare\uff5cCollettore solare\uff5cImpianto solare per acqua calda\uff5cImpianto solare ibrido","url":"https:\/\/service.soletksolar.com\/it\/","logo":"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2025\/11\/cropped-211bdff6-75d9-4868-ba26-75265dcd448d.png","knowsAbout":["Blog","Uncategorized","solar thermal","commercial hot water","solar thermal collectors","flat plate collector","solar collector panels","evacuated tube collector"]},{"@type":"WebSite","@id":"https:\/\/service.soletksolar.com\/it\/#website","url":"https:\/\/service.soletksolar.com\/it\/","name":"Scaldacqua solare\uff5cCollettore solare\uff5cImpianto solare per acqua calda\uff5cImpianto solare ibrido","inLanguage":"it-IT","publisher":{"@id":"https:\/\/service.soletksolar.com\/it\/#organization"},"description":"Shandong Soletks Solar Technology Co., Ltd","potentialAction":{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/service.soletksolar.com\/it\/?s={search_term_string}"},"query-input":"required name=search_term_string"}},{"@type":"BreadcrumbList","@id":"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Solar Water Heater\uff5cSolar Collector\uff5cSolar Hot Water System\uff5cHybrid Solar Power System","item":"https:\/\/service.soletksolar.com\/it\/"},{"@type":"ListItem","position":2,"name":"Blog","item":"https:\/\/service.soletksolar.com\/it\/category\/blog\/"},{"@type":"ListItem","position":3,"name":"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide","item":"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/"}]},{"@type":"Article","@id":"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/#article","headline":"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide","inLanguage":"it-IT","datePublished":"2026-11-11T06:47:34+00:00","dateModified":"2026-11-11T06:54:50+00:00","mainEntityOfPage":"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/","isPartOf":{"@id":"https:\/\/service.soletksolar.com\/it\/#website"},"author":{"@id":"https:\/\/service.soletksolar.com\/it\/author\/soletksolar\/#person"},"publisher":{"@id":"https:\/\/service.soletksolar.com\/it\/#organization"},"image":"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2026\/06\/Centralized-solar-heating-for-Saga-County-town-in-Shigatse-City-1-1024x594.png","description":"Plan a solar space heating system for heating and hot water: load, collector area, buffer tank, underfloor vs radiators, backup and solar fraction."},{"@type":"Person","@id":"https:\/\/service.soletksolar.com\/it\/author\/soletksolar\/#person","name":"soletksolar","url":"https:\/\/service.soletksolar.com\/it\/author\/soletksolar\/","sameAs":["http:\/\/service.soletksolar.com"],"image":"https:\/\/secure.gravatar.com\/avatar\/444480c4715a26b1f63ed7bdff240bbdf33660d6bf21b781a49cd813391c2c2f?s=112&d=404&r=g"}],"markdown_url":"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design.md","html":"<title>Solar Space Heating Combisystem Design &amp; Sizing | SOLETKS<\/title>\n<meta name=\"description\" content=\"Plan a solar space heating system for heating and hot water: load, collector area, buffer tank, underfloor vs radiators, backup and solar fraction.\" \/>\n<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n<link rel=\"canonical\" href=\"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide\" \/>\n<meta property=\"og:description\" content=\"Plan a solar space heating system for heating and hot water: load, collector area, buffer tank, underfloor vs radiators, backup and solar fraction.\" \/>\n<meta property=\"og:image\" content=\"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2026\/06\/Centralized-solar-heating-for-Saga-County-town-in-Shigatse-City-1-1024x594.png\" \/>\n<meta property=\"og:image:alt\" content=\"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide\" \/>\n<meta property=\"og:url\" content=\"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/\" \/>\n<meta property=\"og:site_name\" content=\"Solar Water Heater\uff5cSolar Collector\uff5cSolar Hot Water System\uff5cHybrid Solar Power System\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide\" \/>\n<meta name=\"twitter:description\" content=\"Plan a solar space heating system for heating and hot water: load, collector area, buffer tank, underfloor vs radiators, backup and solar fraction.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2026\/06\/Centralized-solar-heating-for-Saga-County-town-in-Shigatse-City-1-1024x594.png\" \/>\n<link rel=\"alternate\" type=\"text\/markdown\" href=\"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design.md\" \/>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/service.soletksolar.com\/it\/#organization\",\"name\":\"Solar Water Heater\uff5cSolar Collector\uff5cSolar Hot Water System\uff5cHybrid Solar Power System\",\"url\":\"https:\/\/service.soletksolar.com\/it\/\",\"logo\":\"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2025\/11\/cropped-211bdff6-75d9-4868-ba26-75265dcd448d.png\",\"knowsAbout\":[\"Blog\",\"Uncategorized\",\"solar thermal\",\"commercial hot water\",\"solar thermal collectors\",\"flat plate collector\",\"solar collector panels\",\"evacuated tube collector\"]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/service.soletksolar.com\/it\/#website\",\"url\":\"https:\/\/service.soletksolar.com\/it\/\",\"name\":\"Solar Water Heater\uff5cSolar Collector\uff5cSolar Hot Water System\uff5cHybrid Solar Power System\",\"inLanguage\":\"it-IT\",\"publisher\":{\"@id\":\"https:\/\/service.soletksolar.com\/it\/#organization\"},\"description\":\"Shandong Soletks Solar Technology Co., Ltd\",\"potentialAction\":{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/service.soletksolar.com\/it\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Solar Water Heater\uff5cSolar Collector\uff5cSolar Hot Water System\uff5cHybrid Solar Power System\",\"item\":\"https:\/\/service.soletksolar.com\/it\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\/\/service.soletksolar.com\/it\/category\/blog\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\\u003Ctrp-post-container data-trp-post-id=\\u00272025\\u0027\\u003ESolar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide\\u003C\/trp-post-container\\u003E\",\"item\":\"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/\"}]},{\"@type\":\"Article\",\"@id\":\"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/#article\",\"headline\":\"Solar Space Heating with Underfloor Heating and Radiators: Combisystem Design and Sizing Guide\",\"inLanguage\":\"it-IT\",\"datePublished\":\"2026-11-11T06:47:34+00:00\",\"dateModified\":\"2026-11-11T06:54:50+00:00\",\"mainEntityOfPage\":\"https:\/\/service.soletksolar.com\/it\/solar-space-heating-combisystem-design\/\",\"isPartOf\":{\"@id\":\"https:\/\/service.soletksolar.com\/it\/#website\"},\"author\":{\"@id\":\"https:\/\/service.soletksolar.com\/it\/author\/soletksolar\/#person\"},\"publisher\":{\"@id\":\"https:\/\/service.soletksolar.com\/it\/#organization\"},\"image\":\"https:\/\/service.soletksolar.com\/wp-content\/uploads\/2026\/06\/Centralized-solar-heating-for-Saga-County-town-in-Shigatse-City-1-1024x594.png\",\"description\":\"Plan a solar space heating system for heating and hot water: load, collector area, buffer tank, underfloor vs radiators, backup and solar fraction.\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/service.soletksolar.com\/it\/author\/soletksolar\/#person\",\"name\":\"soletksolar\",\"url\":\"https:\/\/service.soletksolar.com\/it\/author\/soletksolar\/\",\"sameAs\":[\"http:\/\/service.soletksolar.com\"],\"image\":\"https:\/\/secure.gravatar.com\/avatar\/444480c4715a26b1f63ed7bdff240bbdf33660d6bf21b781a49cd813391c2c2f?s=112\\u0026d=404\\u0026r=g\"}]}<\/script>"},"_links":{"self":[{"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/posts\/2025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/comments?post=2025"}],"version-history":[{"count":3,"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/posts\/2025\/revisions"}],"predecessor-version":[{"id":2032,"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/posts\/2025\/revisions\/2032"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/media\/1706"}],"wp:attachment":[{"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/media?parent=2025"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/categories?post=2025"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/service.soletksolar.com\/it\/wp-json\/wp\/v2\/tags?post=2025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}