Company Logo
Air PVT Hybrid Solar Panel

Air PVT Solar Panel APVT-590 for Solar Drying, Space Heating and Electricity

SOLETKS APVT-590 is an air-based photovoltaic thermal panel that generates electricity and captures warm air from the same solar surface. It is designed for low-temperature drying, space heating support and projects that need higher total solar energy use from limited installation area.

590 WElectrical maximum power under STC
1551 WPeak thermal power from air heat collection
70-90 m3/hRecommended air flow range
APVTHybrid electricity plus warm air output

An air PVT solar panel is a photovoltaic thermal module that produces electricity from PV cells while collecting warm air from the back or thermal layer of the panel. Unlike a water-based PVT collector, an air PVT panel uses airflow instead of liquid circulation, making it suitable for low-temperature drying, ventilation preheating and space heating support.

Electricity and warm air from one solar installation area.

Standard PV panels generate electricity, but the heat behind the module is usually wasted. An air PVT panel captures part of that heat and moves it through an air channel, creating a second useful energy output without adding a separate solar air collector area.

1
Hybrid solar outputAPVT-590 produces PV electricity and usable warm air from one product, helping projects use solar radiation more completely.
2
Smaller system footprintOne roof or facade surface can support both electrical generation and air heating, which is useful when installation area is limited.
3
Better PV operating conditionsBy moving heat away from the module, the air channel can support lower operating temperature and stronger lifetime energy performance under suitable conditions.
SOLETKS solar air collector technology for warm air applications
Air-based solar thermal products are suitable for drying, ventilation preheating and space heating support. APVT adds PV electricity to the same solar surface.

APVT-590 is strongest where warm air is useful every day.

Air PVT should be positioned around real thermal demand. The product becomes more persuasive when the buyer understands how warm air can reduce electric heating, fossil fuel drying or conventional ventilation heating.

Low-Temperature Drying

Solar warm air can support drying processes that need stable low-temperature heat rather than high-pressure hot water.

  • Agricultural product drying
  • Food, herbs, grains and seed drying
  • Wood, textile or material pre-drying

Space Heating Support

APVT can supply preheated air to reduce heating load in workshops, warehouses, farms and public buildings.

  • Fresh air preheating
  • Winter space heating support
  • Hybrid operation with existing HVAC

Ventilation Preheating

Buildings that require fresh air can use solar-heated air before it enters the indoor ventilation or heating system.

  • Lower backup heating demand
  • Useful for cold and sunny climates
  • Simple air duct integration

Agricultural Facilities

Farms often need both electricity and low-temperature thermal energy for drying, livestock facilities or greenhouse support.

  • Rural energy projects
  • On-site power generation
  • Warm air for controlled drying

Industrial Air Heating

Factories with repeatable warm air demand can use APVT to preheat process air before electric or fuel-based heating.

  • Process air preheating
  • Cleaning and drying lines
  • Hybrid backup heating design

Distributors and OEM Buyers

Buyers searching for air PVT panels may need a product line with specifications, packing data and technical documentation.

  • APVT-590 specification package
  • OEM/ODM cooperation discussion
  • Container planning data available

Use real product data to build trust and attract serious inquiries.

The following data is based on the APVT-590 product parameter sheet. On the live page, this specification table should remain visible instead of hiding all technical information behind a contact form.

Category รายการ APVT-590 Data
รุ่น Product model APVT-590
โครงสร้าง ขนาด 1148 x 2293 x 80 mm
โครงสร้าง Outline area 2.63 m2
โครงสร้าง น้ำหนัก 37 kg
โครงสร้าง Cover material Ultra-clear low-iron single-sided textured tempered glass, 3.2 mm
PV Cell Cell quantity and type 144 pcs, N-type TOPCon monocrystalline
Electrical Maximum power under STC 590 W
Electrical Module efficiency 23.3%
Electrical Maximum system voltage 1500 โวลต์
Electrical Voc / Vmp 51.1 V / 44.45 V
Electrical Isc / Imp 14.31 A / 13.27 A
Electrical Operating temperature -40 to 70 deg C
Electrical Power temperature coefficient -0.28% per deg C
ความร้อน Peak thermal power 1551 W
ความร้อน Peak thermal efficiency 0.59
ความร้อน Air flow 70-90 m3/h
ความร้อน Static pressure 120 Pa
ความร้อน Air interface 100 mm diameter, 2 pcs
Connection Connector and fire rating MC4 connector, IEC fire class C
Packing Loading data 12 units per pallet, 240 units per 40 ft container
การใช้งาน Recommended use Low-temperature drying and space heating

The panel must be designed as both an electrical product and an air heating component.

A successful air PVT project is not just a panel purchase. The system must coordinate PV wiring, air ducting, fan selection, airflow, temperature control, drying chamber or indoor heating demand and backup heating.

Sunlight reaches the APVT panelN-type TOPCon cells generate electricity while the solar surface heats the air channel.
PV side produces powerDC power connects through MC4 connectors to inverter, building loads, grid or storage system.
Air side captures heatAirflow passes through the thermal channel and carries useful heat away from the module.
Fan controls airflowThe design should match 70-90 m3/h airflow and available static pressure for duct resistance.
Warm air enters the applicationThe output can support drying rooms, ventilation preheating, space heating or process air.
Backup keeps operation stableElectric, gas, heat pump or existing HVAC backup can cover night and low-sun periods.

Airflow, duct resistance and daily heat demand decide the value of an APVT project.

Air PVT buyers often focus only on PV power. For a correct proposal, the thermal side must also be checked: airflow, air temperature rise, duct length, pressure loss, drying chamber size, indoor heating load and seasonal operation.

1
Confirm useful thermal loadAPVT works best when the project can use warm air during solar hours, such as drying or fresh air preheating.
2
Keep ducts efficientLong or narrow ductwork increases pressure loss. Fan selection should match the 120 Pa static pressure data and system layout.
3
Control temperature and humidityDrying projects may need air mixing, exhaust control, humidity monitoring and backup heat to protect product quality.
Buyer-friendly sizing logic APVT value = PV electricity + useful warm air + reduced drying or heating energy + better use of limited roof area

For serious inquiries, ask for project location, use case, required air temperature, airflow demand, installation area, duct distance, backup heat source and operating schedule.

Explain when air PVT is better than PV alone or a conventional solar air collector.

A ranking page should not say one technology is always better. It should guide buyers to the right product based on energy demand, system complexity and application.

Question Standard PV Panel Solar Air Collector Air PVT Panel APVT-590
Produces electricity? Yes No Yes, 590 W under STC
Provides warm air? No, heat is mostly wasted Yes Yes, with 1551 W peak thermal power
Best use case Electricity-only projects Air heating or drying only Projects needing both electricity and warm air
System design focus PV string and inverter design Airflow, ducts and thermal demand Electrical design plus airflow and thermal use
Related SOLETKS page PVT Solar Panel Range เครื่องเก็บอากาศ DVC Ask for APVT-590 proposal

Target both product searches and application searches.

Air PVT is a newer search topic, so the page should include multiple natural names: air PVT panel, air-based PVT solar panel, photovoltaic thermal air collector, PV-T air collector, hybrid solar air panel and solar drying PVT panel.

Product Search Intent

Buyers may search for air PVT panel, APVT solar panel, photovoltaic thermal air collector or PV-T air collector.

  • Explain the product in plain language
  • Show APVT-590 specification data
  • Include Product schema and FAQ schema

Application Search Intent

Project buyers may search for solar drying system, solar air heater for drying or solar air heating for buildings.

  • Connect APVT to low-temperature drying
  • Explain airflow and temperature logic
  • Ask for operating schedule and heat demand

Manufacturer Search Intent

Distributors may search for PVT solar panel manufacturer, OEM hybrid solar panel or container loading data.

  • Show packing: 12 per pallet, 240 per 40 ft container
  • Offer technical data sheet and sample discussion
  • Invite OEM/ODM quotation requests

Use existing SOLETKS product pages to strengthen topical authority.

Because air PVT sits between PVT panels and solar air collectors, the live page should link clearly to both product families instead of isolating this product.

SOLETKS PVT hybrid solar panel product image

PVT Hybrid Panel Family

Connect APVT-590 with the broader PVT product range for buyers comparing PV-T, solar PVT and hybrid solar panel options.

SOLETKS DVC solar air collector product image

Solar Air Heating Logic

Use DVC air collector context to explain air heating, drying and ventilation preheating demand.

SOLETKS hybrid solar heating project

Hybrid Solar Projects

Link APVT to real building energy use: electricity, thermal energy, backup systems and system integration.

Ask for the data that makes an air PVT proposal possible.

For APVT, a generic “how much is it” inquiry is not enough. The sales team needs to know the electrical target, air heating use, airflow requirement, drying or heating schedule, installation area and backup system.

APVT RFQ Fields

Project country and city
Application: drying, heating or ventilation
Available roof or installation area
Required air temperature
Airflow demand or duct size
Drying chamber or room volume
Operating hours and season
Backup heating source
Electricity use or grid connection
Quantity or purchase plan

For OEM and distributor inquiries, add target market, annual purchase plan, branding requirement, certification needs and preferred packing information.

Answer buyer questions in a format Google and AI systems can extract.

What is an air PVT solar panel?

An air PVT solar panel is a photovoltaic thermal module that generates electricity from PV cells and captures warm air through an air channel. It is used when a project needs both electricity and low-temperature thermal energy.

What is APVT-590 used for?

APVT-590 is suitable for low-temperature drying, space heating support and ventilation preheating. Typical projects include agricultural drying, industrial warm air preheating, workshops, warehouses, farms and buildings with useful warm air demand.

How is air PVT different from water-based PVT?

Air PVT transfers heat through airflow, while water-based PVT transfers heat through water or heat transfer fluid. Air PVT is useful for drying and air heating, while water-based PVT is usually better for domestic hot water, pool heating or hydronic heating.

Can APVT improve PV performance?

Moving heat away from the module can support better operating temperature conditions. The product parameter sheet notes that, over the life cycle, photoelectric conversion performance can be improved by 10-15% under suitable system conditions.

What technical data is most important for an APVT quote?

The most important data includes project location, installation area, application, required air temperature, airflow demand, duct distance, drying or heating schedule, electrical target and backup heating source.

Is APVT-590 only a solar air heater?

No. A solar air heater provides warm air but does not generate electricity. APVT-590 is a hybrid product that provides both PV electricity and warm air from the same panel surface.

Send your drying or space heating data. SOLETKS can help evaluate whether APVT-590 is the right hybrid solar product.

For a useful proposal, include project location, roof area, required air temperature, airflow demand, application type, operating schedule, backup heat source and expected quantity.